Early Lead Extraction for Infected Implanted Cardiac Electronic Devices: JACC Review Topic of the Week
JACC Review Topic of the Week
Central Illustration
Abstract
Infection remains a serious complication associated with the cardiac implantable electronic devices (CIEDs), leading to substantial clinical and economic burden globally. This review assesses the burden of cardiac implantable electronic device infection (CIED-I), evidence for treatment recommendations, barriers to early diagnosis and appropriate therapy, and potential solutions. Multiple clinical practice guidelines recommended complete system and lead removal for CIED-I when appropriate. CIED extraction for infection has been consistently reported with high success, low complication, and very low mortality rates. Complete and early extraction was associated with significantly better clinical and economic outcome compared with no or late extraction. However, significant gaps in knowledge and poor recommendation compliance have been reported. Barriers to optimal management may include diagnostic delay, knowledge gaps, and limited access to expertise. A multipronged approach, including education of all stakeholders, a CIED-I alert system, and improving access to experts, could help bring paradigm shift in the treatment of this serious condition.
Highlights
• | Infection is a life-threatening complication of implanted CIEDs. | ||||
• | Although clinical evidence and guidelines support extraction of infected CIED, adherence is limited. | ||||
• | Educating stakeholders and optimizing use of technology can help address barriers to explanation of infected CIED. |
Introduction
Cardiac implantable electronic devices (CIEDs) play an important role in the management of cardiac arrhythmias and the prevention of sudden cardiac death.1 As the indications for primary prevention and cardiac resynchronization have expanded alongside an aging population, CIED implantation has increased worldwide over recent years.2,3
Although technological advances have improved both the devices and implantation procedures, cardiac implantable electronic device infections (CIED-Is) remain a significant problem.4 These include pocket infection, systemic infection, and infective endocarditis, each of which can be life-threatening.5-7 The Heart Rhythm Society and the European Heart Rhythm Association (EHRA) have published guidelines for the management of leads and devices, including recommending extraction for CIED-I.5,8 Despite multiple recommendations on prevention, diagnosis, and management strategies, discussions about barriers to optimal treatment and guideline adherence in clinical practice are limited.
The objective of this review is to summarize the literature to provide a comprehensive overview of CIED-Is and management. A structured literature review was performed in MEDLINE via the PubMed interface on October 21, 2020, for papers published in the last 15 years to inform this review. Titles and abstracts identified by the search were reviewed for eligibility based on inclusion criteria. Publications on CIED-I rates, outcomes of management strategies, associated clinical or economic burden such as health-related quality of life, and cost of infection were included. Furthermore, clinical practice guidelines on CIED-I management were captured in addition to papers discussing trends in clinical practice, adherence to guidelines, and/or barriers to optimal treatment. Search strategy and search results can be found in the Supplemental Appendix.
The review will systematically characterize the following: 1) the epidemiology and burden of CIED-Is; 2) clinical outcomes data on various treatment strategies and health care utilization research CIED-Is; 3) an overview of current guidelines on CIED-I treatment; 4) the adherence to consensus and guideline recommendations; and 5) potential barriers to the recommended treatment. We conclude the review with future directions and possible solutions to address barriers to optimal treatment.
CIED-I Epidemiology and Clinical Impact
CIED-Is can lead to serious systemic complications. They can present either as a pocket infection in the chest, typically diagnosed clinically, or a systemic infection, which is confirmed with positive blood cultures. CIED-I rates across the world range from 0.8% to 4.2%.4,9-19 Overall, CIED-I rates within a year of implantation range from 1.2% to 3.4%.11-14 A U.S. cohort study using the National Inpatient Sample database found that 8,060 (4.2%) of 191,610 CIED implantations were admitted for CIED-Is in 2016.18 Among a Danish CIED population (128,045 devices), the overall incidence of CIED-I was reported to be 1.43%.16 A complete summary of infection rates can be found in Table 1.
First Author | Year | Region | Infection Rate, % | Details and Time Frame |
---|---|---|---|---|
Ahsan et al9 | 2014 | United Kingdom | 1.33 | Of 1,798 device procedures performed between November 2004 and May 2009, 24 patients (1.33%) developed infections requiring device removal. |
Chen et al10 | 2020 | Taiwan | 1.4 | During a mean follow-up of 2.9 ± 1.7 y, 17 (1.4%) patients were diagnosed with a CIED infection episode. |
Daneman et al11 | 2020 | Canada | 1.2 | Among 17,584 patients, 215 (1.2%) developed a CIED-related infection during the year after implantation. |
de Bie et al12 | 2012 | Netherlands | 1.1; 2.6 | Of a total of 2,476 patients, the cumulative incidence of CIED after initial device implantation was 1.1% at 1 y and 2.6% at 3 y. |
Eby et al13 | 2020 | United States | 1.28 | The overall infection rate within the first year postimplant was 1.28%. |
Ganesan et al4 | 2019 | Australia | 0.8 | The incidence of CIED infection complication was 0.8% (244 patients [115 in public hospitals and 89 in private hospitals] of 32,364 patients). |
Ludwig et al14 | 2018 | Germany | 3.4 | There were 158 CIED infections in the 12 mo after implantation, an annual risk of 3.4%. |
Nakajima and Taki15 | 2016 | Japan | 1.12-2.8 | The overall infection rate was 1.12% (95% CI: 0.812%-1.505%); however, the rate was 2.77% at the sites with more experience with implantation. |
Olsen et al16 | 2019 | Denmark | 1.43 | The overall incidence of CIED infection between 1982 and 2018 was 1.43% (of 128,045 devices). |
Palmisano et al17 | 2020 | Italy | 1.7 | 49 patients of 2,811 had devices infection at follow-up (median 56.8 mo). |
Rennert-May et al18 | 2020 | United States | 4.2 | 8,060 infections (4.2%) were identified from 191,601 CIED implantations in 2016 via the Healthcare Cost and Utilization Project National Implant Sample database. |
Yang et al19 | 2019 | Korea | 2.7 | 462 infections were reported for 16,908 at follow-up (mean 17.1 mo). |
The WRAP-IT (World-wide Randomized Antibiotic Envelope Infection Prevention trial) multicenter RCT evaluated the clinical and economic burden of CIED-I from the hospital, payer, and patient perspectives. Patients were found to have significantly reduced quality of life at the time of infection diagnosis vs baseline (0.83 ± 0.14 vs 0.75 ± 0.19; P = 0.004). Furthermore, patients with infection had a significant increased risk of death compared with the no infection group (risk-adjusted HR: 3.41; 95% CI: 1.81–6.41; P < 0.001).20 Similarly, the Italian POINTED (Impact on Patient Outcome and health care utilization of cardiac ImplaNTable Electronic Device complications) Registry suggested that CIED-I is associated with poor survival compared with patients with other complications or those with none (P < 0.001).17
CIED-Is may be related to various patient, device and procedural factors (Central Illustration). Patient factors that may increase the risk of CIED-I include renal dysfunction, diabetes, and younger age.13,14,16,19 Oral anticoagulation use and prior CIED-I have also been reported as risk factors.14,16

Cardiac Implantable Electronic Device Infection: Risk Factors, Clinical Presentation, and Addressing Barriers
Cardiac implantable electronic device (CIED) infection may be related to various risk factors, and its clinical presentations can be highly variable. Key stakeholders in the diagnosis and management should be involved in all the steps of CIED infection management to address the barriers. CRT = cardiac resynchronization therapy; EMR = electronic medical record; ER = emergency room; ICD = implantable cardioverter defibrillator; ID = identification.
Economic Burden of CIED-I
The economic burden of CIED-I varies depending on the region. A retrospective analysis of a large U.S. health insurer database showed that CIED-I increases the average annual medical costs by 2.4 times, with a 1-year adjusted incremental expenditure of $57,322 per patient (95% CI: $46,572-$70,484; per patient; P < 0.001).13 The WRAP-IT trial further reported the mean payer costs per infection was $57,978 ± $29,431 for Medicare Advantage and $26,867 ± $14,893 for Medicare Fee For Service.20 In Germany, a retrospective analysis of health claims data reported €15,822 higher costs in the year after CIED-I compared with the year prior to infection (excluding the cost of index device implantation).14 The higher costs were approximately 98% driven by inpatient hospital care.14 A Korean analysis of their National Health Insurance database found that the average cost per person associated with CIED-I was U.S.$17,105,19 which was similar to the United Kingdom (£14,742).21 Regional variations of infection costs per patient is shown in Figure 1.

Regional Variations of Costs per Cardiac Implantable Electronic Device Infection
The global economic burden of cardiac implantable electronic device infection is significant and varies among different nations.
Clinical Outcomes and Health Care Utilization for CIED Extraction
Optimal CIED-I management includes device extraction and is a highly successful procedure. For safety and effectiveness, there were 16 studies reporting on outcomes for patients where the entire study cohort (100%) underwent extraction for the indication of CIED-I. Procedural success was consistently reported to be very high, with most studies reporting rates of >95% (Table 2). Also, procedural complication rates (range 0.0%-4.0%) and mortality rates (range 0.0%-1.0%) were consistently low across all studies32-51 (Figure 2).
First Author | Year | Region | Study Design | Overall Sample Size | Reported Outcomes Definitions | Outcome Definitions | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Procedural Success, % | Major Complication, % | Procedural Mortality, % | ||||||||||||||||||
Chua et al39 | 2000 | United States | Retrospective case series | 123 | 95 | NR | 0 |
| ||||||||||||
Tascini et al35 | 2006 | Italy | Retrospective survey | 121 | 100 | 0 | 0 |
| ||||||||||||
Wazni et al37 | 2010 | United States and Canada | Retrospective study | 825 | 98.2g | 1.5 | NR |
| ||||||||||||
Deharo et al22 | 2012 | France | Matched cohort study | 197 | 98.5 | NR | 1 |
| ||||||||||||
Viganego et al36 | 2012 | United States | Retrospective | 52 | 94 | 3.8 | 0 |
| ||||||||||||
Maytin et al23,c | 2012 | United States | Retrospective cohort study | 334 | 99.1 | 0.6 | 0 |
| ||||||||||||
Rungpradubvong et al40,d | 2014 | United States | Retrospective study | 142 | 98.8 | 1.2 | NR |
| ||||||||||||
Hussein et al24,e | 2017 | United States | Retrospective study | 1063 | 96.3 | 1.4 | 0.2 |
| ||||||||||||
Pecha et al34 | 2018 | Germany | Retrospective review | 52 | 100 | 1.9 | 0 |
| ||||||||||||
Diemberger et al25 | 2018 | Italy | Prospective observational study | 169 | 96.4c | 2.0 | 0 |
| ||||||||||||
Barakat et al26,f | 2018 | United States | Retrospective study | 1159 | 94.4 | 1.9 | 0.4 |
| ||||||||||||
Nishii et al30 | 2019 | Japan | Retrospective review | 109 | 93.6 | 2.8 | 0 |
| ||||||||||||
Nof et al31 | 2019 | Europe | Prospective registry review | 1863 | 93.5 | 3.6 | 0.27 |
| ||||||||||||
Gould et al27 | 2019 | United Kingdom | Prospective observational study | 505 | 98.4 | 1.8 | 0.6 |
| ||||||||||||
Brough et al28 | 2019 | United Kingdom | Retrospective study | 47 | 95b | 4 | 0 |
| ||||||||||||
Black-Maier et al30 | 2020 | United States | Retrospective study | 27 | 93.6 | 0 | 0 |
|

Clinical Outcomes for Cardiac Implantable Electronic Device Extractions in Patients With Cardiac Implantable Electronic Device Infection
Extraction for cardiac implantable electronic device infection is associated with high procedural success (majority of studies showing rates of >95%), low major procedural complication (between 0% to 4%), and very low procedural mortality (0% to 1%). ∗Results reported for the local infection cohort. †Results reported for the early extraction cohort. ‡Results reported for the normal renal function group. §Results reported for patients without abandoned leads.
CIED extraction, when indicated, can be a potentially life-saving procedure. A retrospective study of CIED-I cases from a large academic center between 1991 and 2008 found that antimicrobial therapy without device extraction was associated with nearly a 7-fold higher 30-day mortality (HR: 6.97; 95% CI: 1.36-35.60).38 Additionally, patients with CIED extraction for infection had a 1-year mortality rate of 13.3%, whereas those who were treated with antibiotics only (n = 23) had a 1-year mortality rate of 38.1%.38 Similarly, in an international study examining endocarditis patients, there was an 18.3% difference in 1-year mortality between patients who had their device removed for CIED-I compared with those who did not (19.9% vs 38.2%; P = 0.02) (Figure 3).52

1-Year Mortality for Cardiac Implantable Electronic Device Infection
(A) Extraction vs no extraction. Extraction for cardiac implantable electronic device infection is associated with lower 1-year mortality rates compared with no extraction. (B) Early vs delayed extraction. One-year mortality rates were significantly lower for patients who underwent early extraction compared with delayed extraction. ∗Antimicrobial therapy with complete device removal (n = 376) vs antimicrobial therapy only (n = 21). †CIED infective endocarditis patients with device removal (n = 141) vs no extraction (n = 34). ‡Early extraction (extraction within 10 days after indicated) (n = 83) vs delayed extraction (extraction performed >10 days after indicated) (n = 59). §Early extraction (extraction at initial presentation) (n = 370) vs delayed extraction (extraction after failure of antimicrobial therapy) (n = 23). #Early extraction (<7 days from hospital admission to extraction); bacteremia (n = 127), pocket infection (n = 106); 1-year mortality rates were extrapolated from the Kaplan-Meier curve in Lin et al.53
Timing of CIED extraction, early vs delayed extraction, after infection, also reveals significant differences in 1-year mortality (Figure 3). When extraction was conducted at the initial infection presentation (n = 370), 1-year mortality was significantly lower than those who had extraction after failure of antimicrobial therapy (n = 23) (11.4% vs 43.4%; P < 0.001).38 A retrospective analysis of all consecutive CIED-I patients who underwent extraction at a single U.S. university hospital found similar results. For patients who had extraction within 10 days of diagnosis, a 1-year mortality of 16.9% was reported compared with 33.9% in patients who had extraction after 10 or more days (P = 0.028).40 A 2020 study examining the impact of early vs delayed extraction with infected CIEDs found similar trends of significantly greater 12-month survival rate in patients with bacteremia (P = 0.022) and isolated pocket infections (P = 0.027) when CIED-I extraction occurred early (within 7 days from hospital admission).53 Last, 4 studies reported on reinfection rates associated with complete vs incomplete extraction. Three large single-center studies (2 retrospective and 1 prospective) reported significantly lower rates of reinfection when complete extraction occurred for CIED-I (1.0% vs 50.0%; P < 0.001; 4.3% vs 20.8%; P = 0.006; 5.3% vs 21.4%; P = 0.007). One (retrospective) study failed to report statistical testing for significance.39,54-56
A recent analysis of a Medicare population from 2004 through 2019 provided updated information on device infection and all-cause mortality of these patients.57 CIED-I incidence was 1.1% and only 25% (n = 2,814) of these patients had extraction.57 Cumulative 1-year mortality was 32.4% for patients without extraction at 30 days, compared with 18.5% among patients with extraction within 6 days (P < 0.001).57 Furthermore, any extraction was associated with lower mortality when compared with no extraction (adj HR: 0.73; 95% CI: 0.67-0.81; P < 0.001); and extraction within 6 days was associated with even lower risk of mortality (adj HR: 0.59; 95% CI: 0.52-0.67; P < 0.001).57 Although impactful, analysis from the Medicare database must be used with caution as there are limitations, including the retrospective nature of the data and underrepresentation of the number procedures.
In general, the evidence has demonstrated that prompt CIED extraction is associated with favorable health care resource utilization relative to alternatives. A large U.S. payer database analysis estimated that incremental health care expenditures for patients with an infection managed by inpatient admission with no extraction cost more than double the amount compared with infections managed by extraction in either an inpatient or outpatient setting ($104,077 vs $45,291).58 Furthermore, Rungpradubvong et al40 found that CIED-I patients with early removal (within 10 days of infection diagnosis) were associated with significantly shorter hospital stays compared with their delayed extraction counterparts (17.59 ± 12.64 days vs 43.77 ± 37.77 days; P < 0.001). In addition to shorter hospital stays, early extraction was associated with lower mean all-cause Medicare costs within 12 months postinfection, with extractions occurring on the same day as diagnosis costing an estimated $34,640 vs $76,836 for extractions occurring ≥180 days from infection diagnosis.59
Although the evidence presented supports timely CIED extraction, the context must be considered. Many of these studies are not randomized. Thus, delayed extraction cohorts are more likely to have older, frail patients, including those with end-stage diseases. CIED extraction is not without risk; associated major perioperative adverse events can include cardiac arrest/perforation, dissection, and pericardial tamponade. Also, studies are often limited to specific subgroups and may not be directly comparable. Furthermore, many of these studies may include outcomes from experienced centers with high extraction volumes. Although the positive outcomes reported provide confidence of the procedure, they fail to provide a comprehensive overview of extraction outcomes across all centers and individuals with varied experience.
Guideline Recommendations and Real-World Clinical Practice Patterns
Five current guidelines from professional societies provide recommendations on CIED lead management and extraction: American Heart Association, British Heart Rhythm Society, European Society of Cardiology, Heart Rhythm Society, and EHRA. All report a Class I indication for complete system removal in patients with defined CIED-I (systemic, local, bacteremia, or infection endocarditis). Three of these guidelines explicitly recommended prompt and complete system removal for definite CIED-I.5,7,8,60,61 A summary of the guideline recommendations for CIED-I can be found in Table 3.
Society, Year | Recommendations | Details | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Complete Extraction | Prompt Extraction | ||||||||||||||
AHA, 201061 | × | × |
| ||||||||||||
BHRS, 20157 | × | × |
| ||||||||||||
ESC, 201560 | × |
| |||||||||||||
HRS, 20178 | × | × |
| ||||||||||||
EHRA, 20205 | × | × |
|
Despite these guideline recommendations, a recent analysis of the U.S. Medicare database demonstrated that >8 of 10 patients were not treated according to Class I guidelines for CIED-I (full system extraction).57 Additionally, a global survey of members of 7 arrhythmia societies found regional disparities in the clinical practices for the management of CIED-I. The survey revealed that all regions did not fully comply with current guidelines recommendations.62 It found that only 62% of responders would manage CIED pocket infection with complete system removal and 13.7% would complete no action and wait until the next regular visit.62 The European adherence rate (68.9%) was similar to a Germany single-center experience over 4 decades in which only 57% of CIED-Is were treated with system extraction.56 Furthermore, the physician survey rate in the Asia/Pacific region (41.2%) aligned with 2 other Japanese surveys. One reported a 55.8% annual system removal rate in 2013, and a 2018 web-based survey of 155 Japanese cardiologists reported that 30% of CIED-I cases were treated by entire system removal.15,63
Barriers to CIED Guideline Adherence
A 2020 physician education needs survey was conducted by the EHRA/European Society of Cardiology (ESC) to help assess guideline adherence and potential barriers in effective CIED-I management in clinical practice.64 The 3 main barriers were as follows: 1) identification of the CIED-I; 2) prompt referral; and 3) access to extraction. Identification barriers often reflect gaps in physician knowledge and skills in CIED-I management (25% of extractors and more than 60% of nonextractors reported the need for improvement).64 Referral barriers included factors such as proximity to an extraction center (reported by 18% of responders), ease of access to an extraction center (reported by 37% of responders), or fear of losing a patient to an extracting physician (reported by 14% of responders).64 Other factors included bed constraints, cost, and perceived lack of a diagnosis. Additional factors associated with extraction barriers included patients’ comorbidities, with 92% of responders reporting this affected their choice; age of the patients (reported by 83% of responders); and age of the lead (reported by 73% of responders). Responders were asked what factors may limit a patient from being considered for lead extraction: 77% reported a high risk of procedural mortality, and 44% reported the perceived difficulty or complexity of the procedure (Table 4).64
Barrier Category | Barrier Details | Discussion/Recommendation | ||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Identification |
|
| ||||||||||||||||||||||||||||||
Referral |
|
| ||||||||||||||||||||||||||||||
Extraction |
|
|
Barriers to identification may be caused by lack of optimal communication and coordination. These patients are often seen by specialties other than their implanting electrophysiologists (ie, hospitalists, primary care physicians, general cardiologists, and so on). Furthermore, symptoms of CIED-I can mimic other infections and illnesses and can be overlooked or misdiagnosed. Examples of CIED infection are shown in Figure 4. Referral barriers and patient factors seem to largely influence the decision of whether to use total device extraction.

Examples of Cardiac Implantable Electronic Device Infection
(A) Localized pocket infection. (B) Device erosion with site inflammation (C) AngioVac filter filled with pieces of large vegetations. (D) Large lead vegetation removed with vacuum-assisted aspiration.
Addressing Barriers to Appropriate and Effective CIED-I Management
Because barriers to optimal treatment for CIED-Is are multifactorial, they may be addressed by various approaches and tools. Identification barriers largely stem from the lack of physician knowledge and awareness that can be mitigated with evidence and education. Another strategy is the incorporation of an electronic medical record alert system in which an automatic alert is sent to responsible physicians when a positive culture is registered in a CIED patient’s medical record. An observational study examining the impact of an electronic medical record alert system in individuals with CIED-I demonstrated positive trends in improvement in the time to evaluation and device removal compared with before implementation of the system.65 Many of the cited referral barriers to extraction cannot be easily addressed with one solution, because they involve physicians’ perceptions, preferences, and misconceptions. For example, it is unclear why patients diagnosed with CIED-I would be managed conservatively and why treating physicians are reluctant in seeking expert opinion and a more definite therapy. In many cases, CIED-Is are managed by teams that are not experts in CIED-I management. Creating a team structure that can accurately identify individuals with CIED-Is and efficiently channeling them to appropriate expert care that includes infectious disease specialists and device extraction specialists in a timely fashion could dramatically improve outcomes. For these patients, an explanation about the details of the extraction procedure as a therapy option and potential complications if such a procedure is delayed should be offered and adopted into standard clinical practice. To help address such barriers, a deeper understanding of how these reasons vary across setting, region, and physician type, as well as the relative dominance of such reasons, is key to building on education and resourcing platforms that can help to solve these gaps. It must be considered that untreated, inadequately treated, or delays in optimal treatment for CIED-Is can have consequences not only for the patient but also for the health care system in terms of resource and cost burden. This further supports the need to provide evidence and education to help inform physicians (and health care administrators) to prioritize early complete extraction for CIED-I as indicated by clinical guidelines. A quality initiative with a framework to increase guideline-driven care for patients with suspected CIED-I at hospitals may also address the gaps. Even though there is no existing concept of a center of excellence for lead extraction (ie, how many extractions should be performed), it is important that one must be created with established criteria. As with most implementation challenges, successful interventions need to be multifaceted to address the various barriers to optimal care. These interventions should be directed at the patient, physician, and system level.
Conclusions
CIED-I continues to be a serious and continued problem in clinical practice. Adherence to a guideline-based CIED-I management strategy including appropriate device extraction seems to be low. Barriers related to identification, referral, and perceptions around the extraction procedure are widely prevalent. Addressing knowledge gaps and overcoming the identified barriers in building effective CIED-I management teams and referral networks for timely and appropriate interventions including device extraction could improve the outcomes.
Funding Support and Author Disclosures
This work was supported by Philips Image Guided Therapy Corporation. Dr Lakkireddy is a consultant for Philips and Abbott; and has received honoraria from Abbott, Medtronic, Boston Scientific, and Biosense Webster. Dr Sood is an employee of Philips Image Guided Therapy Corporation. Dr Wu is an employee of EVERSANA which has received funding from Philips Image Guided Therapy Corporation. Dr Rao has received honoraria from Medtronic, Boston Scientific, and Philips for educational activity and consultancy. Dr Sohail is a consultant for Medtronic Inc, Philips, and Aziyo Biologics, Inc. Dr Pokorney receives modest consultant/advisory board support from Boston Scientific, Medtronic, Philips, Bristol Myers Squibb, Pfizer, Sanofi, and Zoll; and has received modest research support from the Food and Drug Administration, Bristol Myers Squibb, Pfizer, Janssen, Gilead, Philips, Sanofi, and Boston Scientific. Dr Blomström-Lundqvist is a consultant for Boston Scientific, Medtronic, Philips, Bristol Myers Squibb, and Cathprint. Dr Piccini is a consultant for Abbott, Biotronik, Boston Scientific, Medtronic, and Philips; has received grants for clinical research from Abbott, American Heart Association, Boston Scientific, and Philips; and is supported by R01AG074185 from the National Institutes of Aging. Dr Granger has clinical research contracts from Boehringer Ingelheim, CeleCor, Bayer, Bristol Myers Squibb, the U.S. Food and Drug Administration, National Institutes of Health, Pfizer, Janssen, and Phillips; has received consulting/honoraria from AbbVie, Bayer, Bristol Myers Squibb, Boston Scientific, Boehringer Ingelheim, Hengrui, Janssen, Pfizer, Lilly, Medtronic, Merck, Novartis, NovoNordisk, and Reata; and has equity from tenac.io. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.
Abbreviations and Acronyms
CIED | cardiac implantable electronic device |
CIED-I | cardiac implantable electronic device infection |
EHRA | European Heart Rhythm Association |
References
1. "Anesthetic management of laser lead extraction for cardiovascular implantable electronic devices". Semin Cardiothorac Vasc Anesth . 2017;21:302-311.
2. "Trends of cardiovascular implantable electronic device infection in 3 decades: a population-based study". J Am Coll Cardiol EP . 2019;5:1071-1080.
3. "16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008". J Am Coll Cardiol . 2011;58:1001-1006.
4. "Complications of cardiac implantable electronic device placement in public and private hospitals". Intern Med J . 2020;50:10: 1207-1216. https://doi.org/10.1111/imj.14704.
5. "European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections-endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID), and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)". Eur Heart J . 2020;41:2012-2032.
6. "The diagnosis and treatment of pacemaker-associated infection". Dtsch Arztebl Int . 2018;115:445-452.
7. "Guidelines for the diagnosis, prevention and management of implantable cardiac electronic device infection. Report of a joint Working Party project on behalf of the British Society for Antimicrobial Chemotherapy (BSAC, host organization), British Heart Rhythm. Society (BHRS), British Cardiovascular Society (BCS), British Heart Valve Society (BHVS) and British Society for Echocardiography (BSE)". J Antimicrob Chemother . 2015;70:325-359.
8. "2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction". Heart Rhythm . 2017;14:e503-e551.
9. "A simple infection-control protocol to reduce serious cardiac device infections". Europace . 2014;16:1482-1489.
10. "Clinical outcomes of patients undergoing a cardiac implantable electronic device implantation following a recent non-device-related infection". J Hosp Infect . 2020;105:272-279.
11. "The predictors and economic burden of early-, mid- and late-onset cardiac implantable electronic device infections: a retrospective cohort study in Ontario, Canada". Clin Microbiol Infect . 2020;26:255-e1-e6.
12. "Cardiac device infections are associated with a significant mortality risk". Heart Rhythm . 2012;9:494-498.
13. "Economic impact of cardiac implantable electronic device infections: cost analysis at one year in a large U.S. health insurer". J Med Econ . 2020;23:698-705.
14. "Incidence and costs of cardiac device infections: retrospective analysis using German health claims data". J Comp Eff Res . 2018;7:483-492.
15. "Incidence of cardiac implantable electronic device infections and migrations in Japan: results from a 129 institute survey". J Arrhythm . 2016;32:303-307.
16. "Incidence of device-related infection in 97 750 patients: clinical data from the complete Danish device-cohort (1982-2018)". Eur Heart J . 2019;40:1862-1869.
17. "Impact on all-cause and cardiovascular mortality of cardiac implantable electronic device complications: results from the POINTED Registry". J Am Coll Cardiol EP . 2020;6:382-392.
18. "Epidemiology of cardiac implantable electronic device infections in the United States: a population-based cohort study". Heart Rhythm . 2020;17:1125-1131.
19. "The burden and risk factors for infection of transvenous cardiovascular implantable electronic device: a nationwide cohort study". Korean Circ J . 2019;49:742-752.
20. "Impact of cardiac implantable electronic device infection: a clinical and economic analysis of the WRAP-IT Trial". Circ Arrhythm Electrophysiol . 2020;13:e008280.
21. "Cardiac implantable electronic device (CIED) infections are expensive and associated with prolonged hospitalisation: UK Retrospective Observational Study". PLoS One . 2019;14:e0206611.
22. "Long-term outcomes following infection of cardiac implantable electronic devices: a prospective matched cohort study". Heart . 2012;98:724-731.
23. "Long-term mortality after transvenous lead extraction". Circ Arrhythm Electrophysiol . 2012;5:252-257.
24. "Cardiac implantable electronic device infections: added complexity and suboptimal outcomes with previously abandoned leads". J Am Coll Cardiol EP . 2017;3:1-9.
25. "The "Subtle" connection between development of cardiac implantable electrical device infection and survival after complete system removal: an observational prospective multicenter study". Int J Cardiol . 2018;250:146-149.
26. "Transvenous lead extraction in chronic kidney disease and dialysis patients with infected cardiac devices". Circ Arrhythm Electrophysiol . 2018;11:e005706.
27. "Predictors of mortality and outcomes in transvenous lead extraction for systemic and local infection cohorts". Pacing Clin Electrophysiol . 2019;42:73-84.
28. "Real-world costs of transvenous lead extraction: the challenge for reimbursement". Europace . 2019;21:290-297.
29. "Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA)". Heart Rhythm . 2009;6:1085-1104.
30. "Lead extraction for cardiovascular implantable electronic device infection in patients with left ventricular assist devices". J Am Coll Cardiol EP . 2020;6:672-680.
31. "Recommendations for extraction of chronically implanted transvenous pacing and defibrillator leads: indications, facilities, training. North American Society of Pacing and Electrophysiology Lead Extraction Conference Faculty". Pacing Clin Electrophysiol . 2000;23:544-551.
32. "Prognosis after lead extraction in patients with cardiac implantable electronic devices infection: comparison of lead-related infective endocarditis with pocket infection in a Japanese single-center experience". J Arrhythm . 2019;35:654-663.
33. "Comparison of outcomes in infected cardiovascular implantable electronic devices between complete, partial, and failed lead removal: an ESC-EHRA-EORP ELECTRa (European Lead Extraction ConTrolled) registry". Europace . 2019;21:1876-1889.
34. "Lead extraction with high frequency laser sheaths: a single-centre experience". Eur J Cardiothorac Surg . 2017;51:902-905.
35. "Management of cardiac device infections: A retrospective survey of a non-surgical approach combining antibiotic therapy with transvenous removal". J Chemother . 2006;18:157-163.
36. "Effect of early diagnosis and treatment with percutaneous lead extraction on survival in patients with cardiac device infections". Am J Cardiol . 2012;109:1466-1471.
37. "Lead extraction in the contemporary setting: the LExICon study: an observational retrospective study of consecutive laser lead extractions". J Am Coll Cardiol . 2010;55:579-586.
38. "Impact of timing of device removal on mortality in patients with cardiovascular implantable electronic device infections". Heart Rhythm . 2011;8:1678-1685.
39. "Diagnosis and management of infections involving implantable electrophysiologic cardiac devices". Ann Intern Med . 2000;133:604-608.
40. "Outcomes of early and delayed removal in patients with cardiac implantable electronic device infection". Paper presented at: 2014Heart Rhythm Society Annual Scientific Sessions ;
May 7-10, 2014 ;San Francisco, CA .41. "Transvenous extraction of pacemaker and implantable cardioverter defibrillator leads using Evolution® mechanical dilator sheath: a single center confirmatory experience". Springerplus . 2016;5:356.
42. "Safety and efficacy of cardiovascular implantable electronic device extraction in elderly patients: a meta-analysis and systematic review". Heart Rhythm O2 . 2020;1:250-258.
43. "Analysis of a 10-year period of lead removal in a referral centre". Interact Cardiovasc Thorac Surg . 2020;31:166-173.
44. "Efficacy and safety of transvenous lead extraction in 108 consecutive patients: a single-centre experience". Interact Cardiovasc Thorac Surg . 2019;28:704-708.
45. "Single-center experience with percutaneous lead extraction of cardiac implantable electric devices". J Cardiol . 2018;71:192-196.
46. "Safety and effectiveness of transvenous lead extraction in octogenarians". J Cardiovasc Electrophysiol . 2012;23:1103-1108.
47. "Cardiac surgeon and electrophysiologist shoulder-to-shoulder approach: hybrid room, a kingdom for two. A zero mortality transvenous lead extraction single center experience". Int J Cardiol . 2019;279:35-39.
48. "Creation of the sole regional laser lead extraction program serving Atlantic Canada: initial experience". Can J Surg . 2016;59:180-187.
49. "Percutaneous extraction of cardiac implantable electronic devices (CIEDs) in octogenarians". Pacing Clin Electrophysiol . 2012;35:841-849.
50. "Transvenous excimer laser-assisted lead extraction of cardiac implantable electrical devices in the Japanese elderly population". J Cardiol . 2020;75:410-414.
51. "Cardiac resynchronization therapy coronary venous left ventricular lead removal and reimplantation: experience from a single center in China". Exp Ther Med . 2019;18:2213-2218.
52. "Clinical characteristics and outcome of infective endocarditis involving implantable cardiac devices". JAMA . 2012;307:1727-1735.
53. "Early versus delayed lead extraction in patients with infected cardiovascular implantable electronic devices". J Am Coll Cardiol EP . 2021;7:6: 755-763. https://doi.org/10.1016/j.jacep.2020.11.003.
54. "Local symptoms at the site of pacemaker implantation indicate latent systemic infection". Heart (British Cardiac Society) . 2004;90:882-886.
55. "Lead extraction for treatment of cardiac device infection: a 20-year single centre experience". Heart Lung Circ . 2017;26:240-245.
56. "A historical perspective of pacemaker infections: 40-years single-centre experience". Europace . 2014;16:235-240.
57. "Pokorney SD. Low rates of guideline directed care associated with higher mortality in patients with infections of pacemakers and implantable cardioverter defibrillators". Paper presented at: American College of Cardiology Scientific Sessions . 2022;
April 2-4, 2022 ;Washington, DC .58. "Incidence, treatment intensity, and incremental annual expenditures for patients experiencing a cardiac implantable electronic device infection: evidence from a large US payer database 1-year post implantation". Circ Arrhythm Electrophysiol . 2016;9:8: e003929 https://doi.org/10.1161/CIRCEP.116.003929.
59. "Treatment patterns, costs, and mortality among Medicare beneficiaries with CIED infection". Pacing Clin Electrophysiol . 2018;41:495-503.
60. "2015 ESC guidelines for the management of infective endocarditis: the task force for the management of infective endocarditis of the European Society of Cardiology (ESC). Endorsed by: European Association for Cardio-Thoracic Surgery (EACTS), the European Association of Nuclear Medicine (EANM)". Eur Heart J . 2015;36:3075-3128.
61. "Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association". Circulation . 2010;121:458-477.
62. "Clinical practice and implementation of guidelines for the prevention, diagnosis and management of cardiac implantable electronic device infections: results of a worldwide survey under the auspices of the European". Heart Rhythm. Association. Europace. . 2019;21:1270-1279.
63. "Infection and migration incidence of cardiac implantable electrical devices in Japan: Web-based survey results". J Arrhythm . 2020;36:780-783.
64. "Knowledge gaps, lack of confidence, and system barriers to guideline implementation among European physicians managing patients with CIED lead or infection complications: a European Heart Rhythm Association/European Society of Cardiology educational needs assessment survey". Europace . 2020;22:11: 1743-1753. https://doi.org/10.1093/europace/euaa218.
65. "Effect of an electronic medical alerts for patients with positive cultures and cardiovascular implantable electronic device". Paper presented at: 2020Heart Rhythm Society Annual Scientific Sessions ;
May 6-9, 2020 ;San Diego, CA .
Appendix
Supplemental AppendixFootnotes
Listen to this manuscript's audio summary by Editor-in-Chief Dr Valentin Fuster on www.jacc.org/journal/jacc.
The authors attest they are in compliance with human studies committees and animal welfare regulations of the authors’ institutions and Food and Drug Administration guidelines, including patient consent where appropriate. For more information, visit the Author Center.